Details of MNS withdrawable low voltage switchgear (cabinet body)
Brand / model: Zhenmin /mns withdrawable low voltage switchgear (cabinet body)
Rated current: 2500 (a)
Short circuit making current: 50 (KA)
Shell protection grade: IP30
Overall dimension: 800*2200*800 (mm)
Product certification: ISO9001
MNS withdrawable low voltage switchgear (cabinet body)
The cabinet frame is a C-shaped bar with modulus =25mm, which is connected by various connectors, self tapping screws and hexagon bolts. The frame structure can be assembled into various forms of cabinets without special tools, with high strength and flexibility
The breaking multifunctional isolation plate is installed between the main bus room and the electrical room, and is made of thermoplastic engineering materials. It has the characteristics of high flame retardance, high strength and high impact, and can effectively prevent the accident caused by the short circuit between the flashover and the bus caused by the fault of the switching element
With standard module design, the cabinet body can be combined into drawer cabinet, fixed cabinet, mixed cabinet and fixed partition cabinet according to customer requirements. The standard specifications of drawer units are 8e/4, 8e/2, 8e, 16e and 24E (e=25mm). Drawers of the same specification can be easily interchanged
Through the operating handle and large interlock, the drawer can be accurately positioned in the connection, experiment, separation and moving positions Each position has corresponding marks on the front panel, which is simple and intuitive
When the circuit breaker is closed, the mechanical interlock device prohibits the drawer from moving to ensure the safety of operation
Enclosure protection grade: IP30, IP40
The cabinet frame is a C-shaped bar with modulus =25mm, which is connected by various connectors, self tapping screws and hexagon bolts. The frame structure can be assembled into various forms of cabinets without special tools, with high strength and flexibility
The breaking multifunctional isolation plate is installed between the main bus room and the electrical room, and is made of thermoplastic engineering materials. It has the characteristics of high flame retardance, high strength and high impact, and can effectively prevent the accident caused by the short circuit between the flashover and the bus caused by the fault of the switching element
With standard module design, the cabinet body can be combined into drawer cabinet, fixed cabinet, mixed cabinet and fixed partition cabinet according to customer requirements. The standard specifications of drawer units are 8e/4, 8e/2, 8e, 16e and 24E (e=25mm). Drawers of the same specification can be easily interchanged
Through the operating handle and large interlock, the drawer can be accurately positioned in the connection, experiment, separation and moving positions Each position has corresponding marks on the front panel, which is simple and intuitive
When the circuit breaker is closed, the mechanical interlock device prohibits the drawer from moving to ensure the safety of operation
Enclosure protection grade: IP30, IP40